+86-757-81992771

TY206-18 3times pre-vacuum Class B Autoclave

  • TY206-18 3times pre-vacuum Class B Autoclave
  • TY206-18 3times pre-vacuum Class B Autoclave
  • TY206-18 3times pre-vacuum Class B Autoclave
  • TY206-18 3times pre-vacuum Class B Autoclave
  • TY206-18 3times pre-vacuum Class B Autoclave
TY206-18 3times pre-vacuum Class B Autoclave
  • Details

Physical Space18L
Sterilizing Temperature121°C,134°C
Water TankOpen-upward water tank
Door LockDouble-controlled
Data Loggerprinter optional and U disk connection
Dry Procedurevacuum drying
DisplayLED
Testvacuum test
Sterilizing RecordThere is a micro-printer optional  and  U disk connection,recording the whole process of sterilizing
Safety FeaturesPressure Release Valve and Computerized diagnosing and alam system
Water Supply SystemReservoirs(3.5L fresh water and 5 liter waste water reservoirs)
Voltage220V±10% 50/60Hz
power1500W/10A
Instrument Containers3 trays
Chamber Sizeφ250mmX355mm(18L)
Net Weihgt50Kg




General Safety Instructions

-Read and understand this manual before attempting to install or operate the sterilizer.

-Make sure that all the installation conditions are fully complied with.

-Ensure that the supply voltage agrees with the supply voltage specified on the type plate of the sterilizer.

-This appliance must be grounded. Connect only to a properly grounded outlet.

-Do not cover or block any openings on this appliance.

-Use this appliance only for its intended use a described in this manual.

-Do not exceed the maximum weight limit of the loads specified in this manual.

-Do not operate this appliance if it has a damaged cord or plug, if it is not working properly, or if it has been damaged or dropped.

-Never must put into the sterilizer inflammables or explosives products.

-The sterilizer may not be operated in areas in which gas or any other explosive volatile substance is present.

-Installation and repair work should only be performed by authorized service technician. Work by unqualified persons could be dangerous and void warranty.

 

General conditions

Position the device on a plane surface with minimum capacity 60kgs.

The sterilizer should be placed on a level worktable.

Improper water level in the chamber could cause a sterilizer malfunction.

Leave at least 10cm between the device rear part and the wall. The clearance required to open the door is 40cm.

Position the autoclave at such a height as to make it possible for the operator to check the whole sterilization chamber and carry out the normal cleaning operations.

The room where the device is installed must be enough ventilated.

Do not install the device near washing basins, taps, etc. where it is likely to be splashed.

Do not lean on the door when it is opened.

Do not place trays , papers, fluid containers, etc. on the sterilizer.




Previous
Next